Home/Power Management

Power Management

Turn standby generators into an energy resource. AI power-peak management, emission reduction, circuit breaker diagnostics and power monitoring connect and optimise your power equipment.

01AI peak-power management
Standby generators × AI

AI peak-power management
& generator optimisation

Turn the standby generator you already have into a power resource. AI forecasts demand, runs the generator at peak moments and keeps emissions within Korean air-quality limits.

See the AI features

One peak sets a year of charges

Korean demand charges are set by the summer/winter peak for 12 months — shaving that peak cuts the whole year's bill.

Unmanaged standby generators

Diesel standby generators emit PM and NOx at every weekly test run, yet have no mandatory abatement.

Renewable intermittency

As renewables grow, fast-responding distributed resources matter more for grid stability.

Demo — from live monitoring to remote site control, group control, statistics and operating-log reports

VEGS web console

Remote control of many sites from the browser — nothing to install

The site generator control panels (PPCS) connect to a central server, so you can watch every generator and direct peak-cut and demand-response (DR) operation from any web browser.

Live monitoring

Generator status, output (kW), load and battery voltage for every site refreshed every 2 seconds, with running, about-to-start and offline sites clearly separated.

Site connection · remote control

Connect to a site panel through the central server for live values, switch DR and peak-cut modes, and operate the generator controller remotely (stop, manual, test, auto, start).

Groups · one-command control

Group sites and start or stop peak-cut and DR with one command, then follow each site's response and progress live.

Events · messaging alerts

Peak-cut pre-warnings, generator start/stop, DR end and battery or communication alarms pop up on screen and are sent to site staff by mobile message.

Statistics · annual totals

Power trend charts and event history by period and site with CSV export, plus fiscal-year monthly output, run hours and peak-cut and DR counts.

Operating-log reports

Generator run records automatically fill in the emission and control facility operating log as a PDF, alongside site registration, staff and treatment-efficiency settings.

How it works

Edge nodes + central AI server

Lightweight nodes on each site collect meter, generator and emission-control signals; training, inference, versioning and monitoring run on a central AI server. Low installation burden, and models improve with data from every site.

  • Lower bills through peak-demand control
  • Simultaneous PM & NOx reduction within legal limits
  • VPP grouping of distributed resources
  • Verified load-run health of standby generators
  • Local and remote control
01

Load-forecast AI

Multi-horizon demand and peak-risk forecasting from usage, grid import, schedules, weather and seasonality.

02

Condition-aware AI

Fuses engine and pre/post NOx, temperature and pressure sensors to estimate efficiency, abatement state and anomalies.

03

Operation-optimisation AI

Combines forecast and state to set generator mode, output and abatement — issued through a safety-constraint layer.

02Circuit breaker diagnostics
Switchgear testing · diagnostics

Circuit breaker diagnostic system

Regularly checks that switchgear breakers will operate when a fault occurs. Test items run automatically in sequence with a pass/fail judgement for each, and results build up a history that reveals deterioration early.

Demo — test run (per-phase operating waveforms and results) and history analysis

HV breaker (VCB)

HV circuit breaker diagnostic system

  • Operating characteristics (close/open time, chattering, phase spread), control-circuit and power-frequency withstand, insulation resistance, contact resistance and vacuum tests in one run
  • Live R/S/T operating waveforms and values, automatically judged pass, caution or fail against limits
  • Contact control units and instruments (insulation tester, voltage/current meters, resistance meters) linked for step-by-step automatic testing
  • Year-by-year test history shows trends in operating time and coil resistance, flagging breakers that need attention

Demo — full test sequence and individual instrument tests

LV breaker (ACB)

LV circuit breaker diagnostic system

  • Full test sequence run automatically: close/open characteristics, insulation resistance, withstand voltage, main-circuit resistance, control-circuit leakage, over- and under-voltage operation
  • Coil current and R/S/T/N and auxiliary-contact waveforms give opening time, phase spread and peak coil current
  • Live breaker status and input contacts, with emergency stop, step retest and skip
  • Individual instrument tests, contact I/O checks and waveform capture for on-site inspection
03Track record
References

Power-sector track record

01

Demand response with standby generators

Mixed-use and knowledge-industry buildings — demand-response systems built, installed and in operation

02

Peak-demand control systems

Knowledge-industry buildings — built and commissioned, with live data collection and analysis

03

Generator combined-control system

Automatic generator start and peak control at set thresholds — developed and delivered

04

Power equipment diagnostics

Performance-diagnosis system for intelligent HV breakers — condition diagnosis and failure prediction (power-generation utility)

05

Power monitoring & alarms

Power-monitoring control panels and custom metering/alarm systems (air quality, pollution, power)

Energy savings,
designed for your site

Share your equipment and goals — we will review how to apply it.